Quick Start Guide
Install FC in the hydraulic oil cooler – Verify O-ring has sealed properly.
Install FC in the hydraulic oil cooler – Verify O-ring has sealed properly.
Run Wire from the battery - to fuse (not supplied) - to one of the FC 3/8″ fast-on lugs (Do not connect to battery).
Run a wire from the other FC 3/8″ fast-on lug to the fan motor Positive.
Run a wire from the fan motor Negative to the battery ground.
Connect FC 1/4″ fast-on to machine ground.
Inspect for proper connections – and attache Positive wire to the battery.
Depress Button - fan should spin in the correct direction.
The controller is now ready to use at the factory default temperature of 120F.